There are 43 Params configured when you install and setup Web ViewPoint Enterprise. They are as follows:
1. ACTION-COLLECTOR
Name of the EMS collector to which alerts sent to Enterprise Manager via JSON are logged.
Default: $0
2. ALERT-EMS-LOG
Log Alerts to EMS.
Default: Yes
3. ANALYZER-COLLECTION-TIME
Time at which the collection should run by Event & Storage Analyzer modules. The data collection for both Storage and Event Analyzer modules takes place once every day.
Valid Range: 00:00 to 23:59
Default: 00:05
The changed settings do not come into effect until after the next run of the collector. In other words, the WVP E’s SA/EA modules reads the configuration file after it has finished collecting for that day and it only runs once every day. So, if the user changes the run time the following are possible scenarios:
Collector run scenarios | |||
Original Run time | New Run time | Has run today? |
Effect on Collection
|
1:00 pm | 8:00 pm (later than the original schedule) |
No (i.e., current time is prior to 1pm)
|
Collector will run at 1:00 pm today and will run at 8:00 pm from the next day onward. |
1:00 pm | 8:00 pm (later than the original schedule) |
Yes
|
Collector will run at 1:00 pm the next day ,read the new settings and run at 8:00 pm from the next day onward. Note that it will not run again today. |
1:00 pm |
10:00 am (before the original schedule)
|
No | Collector will run at 1:00 pm today and will run at 10:00 am from the next day onward. |
1:00 pm | 10:00 am (before the original schedule) | Yes | Collector will run at 1:00 pm today, read the new settings and run at 10:00 am from the next day onward. |
4. ANALYZER-DATA-RETAIN
Maximum number of days to retain Event Analyzer & Storage Analyzer data collection. This works as the cleanup logic for the newly created store subvolumes.
Valid Range: 1 – 180
Default: 90
5. ANALYZER-STORE-VOL
Guardian Volume where EA & SA files are stored. Storage volume is the name of Volume where Event Analyzer should store its files. One file is created daily, named EAACT, and is stored in a subvolume named ‘EAyymmdd’, where ‘yymmdd’ represents the day on which the action events were generated.
Default: $DSMSCM
6. AUTOLICENSE
Whether at 60 days before License expiration date, should WVP E check for new License via internet.
Default: Yes
7. CCMOPER-AUTHENCACHE
Period (in seconds) for which MFA token will be cached.
Default: 300
8. CCMOPER-TIMEOUT
Period (in seconds) CCMOPER stays alive with the recent user’s access id.
Default: 600
9. CONFIG
Guardian Volume.Subvolume location where the SSLCONF file is located.
Default: SSLCONF
10. EA-COLLECTORS
Collectors whose log files are scanned daily by Event Analyzer module. Multiple collectors can be added whose log files should be scanned daily. You can specify up to 25 collectors in total.
Default: $0
11. EA-CPU-THROTTLE
Maximum CPU busy(%) Event Analyzer should use during its nightly work.
Default: 5
12. EMSLINK-BUSY-MAX
Maximum CPU Busy % the EMS query module may use when querying for a search string.
Valid Range: 5 – 80
Default: 5
13. EMSLINKTIMEOUT
The amount of time after which Events Query module should timeout when it does not receive a request from the user.
Valid Range: 5 – 80
Default: 5
14. ENFORCE-SECURITY
Option to enable the user permissions and access control feature. If this feature is enforced then it allows only the users who have permissions to Web ViewPoint Enterprise to logon.
Default: No
15. EVENTS-PAGE-SIZE
Number of Events which should be displayed on a browser page, before older events are removed.
Valid Range: 100 – 1000
Default: 1000
16. EVENT_LOG_COLLECTOR
EMS collector WVP E should write its messages to.
Default: $0
17. EXECUTION-LOG
This is a runtime requirement for WVPPREF and UMPGATE.
18. FILTERFILE-LOCATION
Where you keep your EMS Filter files ($VOL.SUBVOL). This list of filter files is displayed on the Events settings screen of Web ViewPoint Enterprise.
19. HIDEACKS
Hides the acknowledged EMS Events from the Events View.
Default: No
20. LISTENER-PORT
Port number used by Listener Process.
Valid Range: 1025 – 65535 or 443.
Default: 8787
21. LISTENER-PROCESS
Process name used by the Listener Process.
Default: $WVLST
22. LITEAUTH
Indicates whether the light version of Web ViewPoint Enterprise, requires Logon.
Default: No
23. MAXPROCESS
The maximum number of UMPGATE processes that can run at the same time.
Default: 20
24. MULTILANGSUPPORT
Character set, text portions of EMS Events should support. This specifies whether multi-language character support is required for displaying of EMS messages in Events.
Default: English
25. NUMSTATIC
The maximum number of static UMPGATE processes that can be active.
Default: 10
26. OSSPPD-PROCESS
Name of the SNMP process, if SNMP is to be used.
Default: $USNMP
27. OSSSYSLOG-PROCESS
Name of the SYSLOG process, if SYSLOG is to be used.
Default: $UMPSL
28. OUT-TCP-PROCESS
TCP Process Web ViewPoint Enterprise uses to send out Alerts.
Default: $ZTC0
29. PATHWAY-01
Location ($VOL.SUBVOL.FILENAME) where you have your PATHMON programs in.
Default: $SYSTEM.SYSTEM.PATHMON
30. PROCMAN-PROCESS
Process name used by the PROCMAN Process.
Default: $WVPMN
31. RDF-LOCATION
Where your RDF environment ($vol.subvol) is present. This is used by WVP E’s alert module to monitor & report on RDF metrics.
Default: $SYSTEM.RDFCOM
32. SA-OLDFILES
The value for this field is used to determine what files will be included in the old file count in Storage Analyzer (i.e. those files that do not have a used date within the number of days specified, thus being considered “old”). Files meeting this criteria will show as “Old files” in Event Analyzer.
Valid Range: 1 – 1000
Default: 365
33. SA-RELOAD
The files whose index levels are greater than or equal to the specified value will only be selected for collection. The value for this field is used to calculate the number of reloadable files for disks.
Valid Range: 1-255
Default: 3
34. SAVEEVENTS
This specifies the EMSLINK whether to show the Save Events to Log option on the settings screens. If SAVEEVENTS is NO, the Save Events to Log feature is disabled and the option does not appear on the Events Settings screen.
Default: No
35. SCROLL-DELAY
Controls the speed at which the events are displayed on the Events screen.
Valid Range: 0 – 100
Default: 0
36. SEND-RESET
Specifies whether the mail server requires RESET during mail delivery handshake.
Default: Yes
37. SEND-SMS-DIRECT
Indicates if you want to send SMS alerts directly via SMS server instead of Phone Carriers.
Default: No
38. SEND-SNOW-VIA-JSON
Use special JSON format when sending Events to ServiceNow.
Default: No
39. SMTP-PORT
SMTP Port to be used for alert Email/SMS delivery notifications. Set the SMTP port to 25 for non-secure SMTP servers.
Valid Range: 1 – 65535
Default: 587
40. SMTP-TIMEOUT
This allows the user to specify the amount of time (in milli seconds) after which UMPDRNE should timeout when it does not receive a request from the SMTP server.
Default: 500
41. SNMP-VERSION
Indicates the version of SNMP, if it is to be used.
Default: v2
42. TCP-PROCESS
TCP Process used by Web ViewPoint Enterprise.
Default: $ZTC0
43. WEBLOCATION
The OSS Directory where Product’s UI library files should be stored in.
Default: /usr/tandem/wvpe