Web ViewPoint Enterprise Knowledge Base
< All Topics
Print

How can I configure Alert Delivery via SMS Text?

Alerts via SMS using SMPP Protocol:

SMS text messages routing between applications and SMPP gateways can be done using SMPP (Short Message Peer-to-Peer) protocol. Web ViewPoint Enterprise supports below methods:

    • SMS via SMS Server: Performs the SMPP client server method using TCP/IP protocol.
    • SMS via API: Performs the SMPP protocol using REST APIs.

1. Go to OSS space, create a directory named wvpesmsv in the following location /usr/tandem.

Commands:

cd /usr/tandem

mkdir wvpesmsv

Example: /usr/tandem/wvpesmsv

2. Transfer the sms.tar file to the newly created directory and run the below command to extract the contents.

tar -xvf sms.tar

/usr/tandem/wvpesmsv: tar -xvf sms.tar

x lib/jsmpp-2.3.9.jar, 387029 bytes, 756 tape blocks

x lib/log4j-1.2-api-2.13.1.jar, 201684 bytes, 394 tape blocks

x lib/slf4j-api-1.7.30.jar, 41472 bytes, 81 tape blocks

x lib/slf4j-simple-1.7.30.jar, 15239 bytes, 30 tape blocks

x sms.tar, 1352704 bytes, 2642 tape blocks

x wvpe-sms.jar, 699825 bytes, 1367 tape blocks

x wvpe-sms.sh, 470 bytes, 1 tape blocks

x wvpeSMSStart.sh, 501 bytes, 1 tape blocks

x wvpe_sms_configuration.properties, 171 bytes, 1 tape blocks

3. Depending on which protocol the user chooses to use (i.e., SMS via SMS server or via API) the wvpe_sms_configuration.properties.sh file needs to be changed.

    • For SMS via SMS Server

Edit wvpe_sms_configuration.properties.sh file and update the below options as needed:

sms_sender_type=smsc

smsc_ipaddress=10.20.30.40

smsc_port=8686

system_id=SYSID

password=password

system_type=MHS

number_type=1

numbering_plan_indicator=1

sender_phone_number=1234567890

    • For SMS via API

For SMS via API, the wvpe_sms_configuration.properties.sh file needs to be changed with the below contents:

sms_sender_type=https

https_path=https://domain.name/b2c/mtk/SmSend?CharsetURL=UTF-

username=username

password=password

4. Edit wvpeSMSStart.sh. Change blue box to current path. Check all other paths exist or updated them.

Give execute permission to the script file using the below command:

chmod 755 ./wvpeSMSStart.sh

5. If the TCP Process is different from $ZTC0, define the specific process name (add_define =tcpip^process^name file=\$NAME) in the umpSysLogStart.sh file.

#!/bin/sh

cd /usr/tandem/wvpesmsv

export _RLD_LIB_PATH=$_RLD_LIB_PATH:/usr/tandem/javaexth11/lib

export JAVA_HOME=/usr/tandem/nssjava/jdk180_l80/

export JREHOME=$JAVA_HOME/jre

export PATH=/usr/tandem/javaexth11/bin:$PATH

export DEBUG_PROG=’run -name=/G/usdp’

add_define =tcpip^process^name file=\$NAME

run -name=/G/usdp /usr/tandem/nssjava/jdk180_l80/bin/java -cp lib/jsmpp-2.3.9.jar:lib/log4j-1.2-api-2.15.0.jar:lib/slf4j-api-1.7.30.jar:lib/slf4j-simple-1.7.30.jar:/usr/tandem/javaexth11/lib/tdmext.jar:wvpe-sms.jar com.idelji.wvpe.sms.SendSMS  

6. On guardian, add the persistent process information via SCF. To do so, go to SCF prompt, modify the required fields as mentioned below and run the lines (as shown below):

a. Change the CPU value if necessary.

b. Change the DEAFULTVOL location. This is the default volume of the user who is logged on to NonStop.

c. Make sure the OSS path /usr/tandem/wvpesmsv/wvpeSMSStart.sh is the same one you created in Step 1.

ADD PROCESS $ZZKRN.USDP , &

AUTORESTART 2 , &

CPU 03 , &

DEFAULTVOL $IDEL00.QABKCOL , &

HIGHPIN ON , &

HOMETERM $ZHOME , &

INFILE $ZHOME , &

NAME $USDP0 , &

ASSOCPROC $USDP , &

OUTFILE $ZHOME , &

PRIORITY 146 , &

PROGRAM $SYSTEM.SYSTEM.OSH , &

SAVEABEND OFF , &

STARTMODE MANUAL , &

STARTUPMSG “-osstty -p /usr/tandem/wvpesmsv/wvpeSMSStart.sh <- >>/tmp/wvpeSMSLog.out 2>>/tmp/wvpeSMSLog.err” , &

STOPMODE STANDARD , &

TYPE OTHER, &

USERID SUPER.SUPER

7. To start the process (in SCF): START PROCESS $ZZKRN.USDP

8. Verify that the process is running by running the below command in SCF.

-> Status PROCESS $ZZKRN.USDP

NONSTOP KERNEL – Status PROCESS NSCLOUD.$ZZKRN.#USDP

Symbolic Name               Name         State           Sub    Primary PID     Backup PID         Owner

USDP                             $USDP0  STARTED                    3 ,655               None               255,255

USDP                             $USDP    STARTED                    3 ,830               None               255,255

9. To stop the process (in SCF): ABORT PROCESS $ZZKRN.USDP

10. Output will be written to the tmp/wvpeSMSLog.out. 

cat /tmp/wvpeSMSLog.out

New code 20000 4204

Configuration: smsSenderType=smsc,smscIPAddress=10.20.30.40,smsPort=8686,syst

emId=SYSID,password=password,systemType=MHS,numberType=1,numberingPlanIndicator=1,senderPhoneNumber=1234567890.

Receiver Phone Number: 1234567890 Message: WVP Enterprise Alert Server: \RADV

Date: 2021-Dec-13 Time: 21:44:46 Severity: Minor Alert Type: Notification Metric: %% Busy Object: 01 Expected: less than 1% Actual: 16% Addl Info: test for phone server